logo
Shenzhen Huanyu Dream Technology Co., Ltd
Produits
le blog
À la maison > le blog >
Blog d'entreprise sur Dual Wavelength 660nm and 850nm LED COB Module Technical Specifications and Testing
Événements
Contacts
Contacts: Ms. Cara
Faxeur: 86-755-27253399
Contactez-nous maintenant
Envoyez-nous un mail.

Dual Wavelength 660nm and 850nm LED COB Module Technical Specifications and Testing

2026-11-20
Latest company news about Dual Wavelength 660nm and 850nm LED COB Module Technical Specifications and Testing
Dual Wavelength 660nm & 850nm LED COB Technical Evaluation and Electrical Testing
Engineering Analysis of Light Therapy Module Architecture, Circuit Separation, and Thermal Sensing Integration | Shenzhen Huanyu Dream Technology Co., Ltd
1. Structural Overview & Wavelength Architecture
Phototherapy device engineering requires precise spectral distribution combined with robust thermal management. Dual-wavelength Chip-on-Board (COB) architectures integrate distinct semiconductor dies onto a unified substrate, allowing fixture designers to deliver targeted optical spectral bands without requiring separate single-color packages.
In phototherapy equipment design, the combination of visible red light and invisible near-infrared light serves distinct biological optical targets. The 660 wavelength red light band targets superficial optical absorption, whereas the 850 wavelength near-infrared band delivers deeper penetration through tissue layers. Integrating both emitter sets into a single circular COB substrate reduces optical alignment complexity and standardizes secondary lens pairing.
Probe contacting circular COB board terminal pads during electrical continuity test
Figure 1: Initial terminal pad probe connection on the dual-channel circular COB module substrate.
Key Circuit Separation Principles:
Independent positive and negative terminal paths (+660/-660 and +850/-850) prevent cross-talk between red and near-infrared LED arrays.
Dedicated trace routing allows pulse-width modulation (PWM) or independent channel current driving for customized treatment protocols.
On-board thermal monitoring terminals enable real-time temperature telemetry directly at the substrate level.
2. Technical Specifications & Key Parameters
The parameters below outline the substrate configuration and electrical terminal interface verified during bench testing:
Parameter Key Value / Specification Interface Description
Red Wavelength 660 Positive (+660) & Negative (-660) Terminal Traces
Near-Infrared Wavelength 850 Positive (+850) & Negative (-850) Terminal Traces
Thermistor Interface NTC Integrated Substrate Temperature Sensor Contact
Parameter Interpretation for Systems Design:
660 Band: Emits intensely in the visible red spectrum. Demands precise forward current control to prevent junction overheating during high-intensity illumination cycles.
850 Band: Emits in the near-infrared region, appearing as a faint purplish optical glow under camera sensors due to low visible spectrum leakage. High radiometric efficiency requires stable current regulation.
NTC Component: The thermistor interface allows external control electronics to actively read board temperature, triggering dynamic current reduction or shut-off if threshold temperatures are exceeded.
3. Electrical Activation & Light Emission Test Procedure
System verification is conducted via direct terminal probing. The step-by-step test sequence confirms optical functionality across both discrete spectral channels:
  1. Channel 1 Probe Connection (660 Wavelength): Test probes are applied to the designated +660 and -660 substrate contact pads. Upon applying forward voltage, the red LED array illuminates uniformly, demonstrating full optical saturation across the circular array.
  2. Channel 2 Probe Switching (850 Wavelength): Test probes are transferred to the +850 and -850 contact pads. The near-infrared array activates, exhibiting the signature faint purple optical output under image sensors typical of 850 band emitters.
  3. Silkscreen & Thermal Interface Audit: Trace markings (+660, -660, +850, -850, NTC) are visually audited under magnification to verify clear pad polarity identification and sensor continuity.
Active lighting test of 660nm red LED COB module emitting bright red light
Figure 2: Active emission test of the 660 red wavelength channel producing intense uniform red light.
Close up shot of 850nm near infrared LED array and clear PCB silkscreen text markings
Figure 3: Close-up of the 850 near-infrared LED array showing silk-screen pad markings (+660, -660, +850, -850, NTC).
4. Engineering Selection Criteria & Application Boundaries
When evaluating dual-spectrum COB modules for light therapy equipment, thermal performance and electrical isolation are the primary engineering bottlenecks.
Selection Guidelines:
Verify driver compatibility with dual independent DC output channels if simultaneous or alternating pulse stimulation is required.
Ensure driver board microcontroller firmware supports NTC thermal sensor inputs for over-temperature protection feedback loop integration.
Select heat sink structures capable of dissipating thermal load during concurrent operation of both 660 and 850 channels.
Application Scope & Operating Boundaries:
Suitable Applications: Targeted phototherapy lamps, beauty light therapy panels, localized recovery modules, and custom dual-spectrum optical arrays.
Operating Limitations: This module requires active temperature monitoring via the NTC connection; operating without thermal feedback control under high drive current may lead to thermal degradation.